| PECULIARITIES OF MICRO-INVERTER: |
 |
MICRO-INV Is 100% in the form of sine-wave model |
 |
No damage on caused to the gadgets which are runned on MICRO-INV, as it provides with
100% sine-wave output.
As a result each and every medical Inurements can be runned |
 |
MICRO-INV. is fully automatic. Even there is no humming and thereby no noise pollution |
 |
It has AVR O/P for best battery back-up |
 |
Battery of inverter gets charged according to its necessity |
 |
MICRO-INV. is battery have automatic over and under charging cut off |
 |
MICRO-INV. battery have also high and low voltage cut off |
 |
MICRO-INV. has 5 times auto start facility and also the over load facility |
 |
It provides Smooth as well as 100% sine wave output which takes care of your gadgets
sensitivity |
|
| |
| MODELS OF INVERTER: |
| MODIFIED SINEWAVE INVERTER: |
| PRODUCTS |
MODEL |
BATTERY |
| HOMELIGHT UPS |
375VA |
12V(1) |
| HOMELIGHT UPS |
625VA |
12V(1) |
| HOMELIGHT UPS |
800VA |
12V(1) |
| HOMELIGHT UPS |
1400VA |
12V(2) |
| |
|
|
|
|
| PURE SINEWAVE INVERTER: |
| PRODUCTS |
MODEL |
BATTERY |
| HOMELIGHT UPS |
800VA |
12V(1) |
| HOMELIGHT UPS |
1400VA |
24V(2) |
| HOMELIGHT UPS |
2500VA |
36V(3) |
| HOMELIGHT UPS |
3500VA |
48V(4) |
| HOMELIGHT UPS |
5000VA |
96V(8) |
|
|
|
| |
| USE OF FACILITIES IN INVERTER: |
 |
RE-START SWITCH: |
When Inverter gets shut down it can be restarted with the help of ON /OFF Button as well as its power can be cut off even it is inverter mode |
|
 |
INDICATION: |
MAINS : Mains indication will be shown ON when inverter will be
receiving electricity supply
UPS : When electricity fails battery of inverter will get on
BACKUP Position and UPS indication will get ON |
|
 |
CHARGING: |
During the charging of battery CHARGING indication will start blinking
and When Battery gets fully charged, indication will remain
continuously on |
|
 |
LOW BATTERY: |
When inverter will be working on battery backup and when
battery will be about to get low, this indication will turn on |
|
 |
OVER LOAD: |
OVER LOAD Indication will turn on if inverter will be used more than
its Output after restarting it 5 times |
|
|
| |
| TECHNICAL SPECIFICATIONS: |
| ALL CODES AND SWITCHES: |
 |
BLACK CODE : |
To be given with Negative(-) point of battery |
|
 |
RED CODE : |
To be given with Positive(+) point of battery |
|
 |
MAINS CODE : |
To be given plug where electricity supply is on and in which phase is to
be on right hand side |
|
 |
OUTPUT SOCKET : |
The supply of instrument which are to be taken from output socket
witch is on the right side of Phase (P) |
|
 |
INV. TO UPS SWITCH : |
When computer is to be runned through inverter the switch given on
back side of inverter should be kept in up position it towards the 'C'
side |
|
|
| |
| TECHNICAL INFORMATION: |
 |
INPUT VOLTAGE |
230V A.C. |
|
 |
INPUT FREQUENCY : |
50 Hz |
|
 |
OUTPUT VOLTAGE : |
230V (± 10%) |
|
 |
OUTPUT FREQUENCY : |
50 Hz (± 1 Hz) |
|
 |
INPUT CHARGING : |
120V TO 280V (INV. MODE),
VOLTAGE RANGE 170V TO 270V (UPS MODE) |
|
 |
HIGH VOLTAGE CHANGE OVER: |
280V |
|
 |
LOW VOLTAGE CHANGE OVER: |
120V (INV.) » 170V (UPS) |
|
 |
BATTERY VOLTAGE: |
Acc to the model of inverter |
|
 |
BACKUP TIME: |
It can be taken on battery's AMP range and on battery's
condition as well on what load inverter is working on.
Batt. V x Batt. AMP x P.F. = Backup time
Load in watt |
|
 |
INV. INSTALATION: |
Battery is to be annotate with battery wire and, then
after Main wire pin is to be inserted in mains plug, in
which phase should be on right side. The electricity
phase of the instruments which are to be unned on
inverter is to be cancelled and plug it into inverter's
O/P. |
|
|
| |